All the filers in our environment are multipathed. Requirement of Multipathing:
System requirements
Multipath storage for active/active configurations is available only on the following storage system models:
FAS900 series
FAS2020 and FAS2050 systems
FAS30xx series
FAS3140 and FAS3170
FAS6000 series
SA200
SA300
SA600
Active/active configuration-type requirements
Multipath Storage is available for the following types of active/active configurations:
· Standard active/active configurations
· Mirrored active/active configurations
· Stretch Metro Clusters
Your active/active configuration must be installed and fully operational. Your configuration testing should include successful failover and giveback.
Note: Fabric-attached MetroClusters have redundant disk paths by default; no special configuration is necessary.
Disk shelf requirements
Multipath Storage for active/active configurations is available for only the following combinations of disk shelves and modules:
DS14mk2 FC or DS14mk4 FC disk shelves with ESH2 or ESH4 modules
DS14mk2 AT disk shelves with RoHS-compliant AT-FCX modules
Best practice recommendation
If any loop in your active/active configuration is cabled for Multipath Storage, every loop should be cabled for Multipath Storage. This is the recommended best practice.
Note: If you have a mixed configuration in which some loops are cabled for Multipath Storage and some are not, the system displays a configuration error message when you boot the system or when a disk on a loop that is cabled for Multipath becomes single-pathed.
Monday, February 2, 2009
Subscribe to:
Posts (Atom)